Power Connections
The NX-P is rated 100-240V 50/60Hz, operates over 90-264V 50/60Hz. Do not connect it to power outside this range.
The provided Tru-One cable is not fitted with a country-specific plug.
Please install a plug that meets local and national electric codes and is suitable for the country's specific power outlet types.
A 3-prong grounding-type plug must be installed following the plug manufacturer’s instructions. The table below shows some possible pin identification schemes; if the pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician.
A cable with a NEMA 15-5P plug is provided for use of the NX-P in the US and Canada. The approved cable must be used in North America.
Wire Color (Standard EU Code) | Pin | Symbol |
Brown | Live | L |
Blue | Neutral | N |
Yellow/Green | Ground | ![]() |
- Check the Power Switch and ensure that is set to the OFF position.
- Insert the provided power cable into the MAINS IN connector and connect the cable to a properly protected and grounded power outlet.
- Turn on the NX-P by toggling the power switch to ON.